1.General Introduction

Honeywell BW Clip single gas detector is a portable type with most user-friendly, reliable and cost-effective way to ensure safety, compliance and productivity, provides up to three years maintenance free operation, just turn on the device and it runs continuously, no need for calibration, sensor replacement, battery replacement or battery charging. That means great reliability and no downtime. Plus, with the two-year BW Clip Series for H2Sor CO, you can put the device in a hibernation case when you’re not using it for a week or more and extend its life by that period of time.

There are two types available, BW Clip type provides standard operation and no calibration; BW Clip Real Time type which includes a real-time gas level display and the ability to calibrate the device. Both types Compatible with both the MicroDock II and the IntelliDoX instrument management systems, the BW Clip Series is engineered to the highest standards of quality and reliability, keeping you safe and compliant. The Standard Package including: Detector complete with specified sensor, stainless steel alligator clip and concussion-proof housing, Test cap, Instructions.

2.General Specifications

Items

BW Clip

Size

1.6 x 2.0 x 3.4 in. / 4.1 x 5.0 x 8.7 cm

Weight

3.2 oz. / 92 g

Temperature

H2S:-40 to +122°F/-40 to + 50°C

CO:-22 to+122°F/-30 to + 50°C

O2:-4to  +122°F  /-20 to + 50°C

SO2:-22 to +122°F/-30 to +50°C

Humidity

5% - 95% RH (non-condensing)

Alarms

Visual, vibrating, audible (95 dB); Low, High

Self -tests

Activated detectors automatically perform one internal diagnostic test every 24 hours

Battery Life

Two years (H2S, CO, O2 or SO2) or three years   (H2S or CO)  depending on the version

Event Logging

35 most recent   events

Ingress Protection

IP66/67

Certification Approvals

ATEX, IECEx, CE, UL

Warranty

Two or  three   years from activation (given normal operation), plus one  year shelf life (6 months for O2).

Up to three years for two-year  H2S and CO detectors when used with  the hibernation feature,  limited to 24 months of detector operation.


3.Sensor Specifications

Gas

Measure Range

Low Alarm Level

High Alarm Level

H2S

0-100ppm

10ppm

15ppm

CO

0-300ppm

35ppm

200ppm

O2

0 to 25%

19.5%

23.5%

SO2

0-100ppm

5ppm

10ppm